Front view – Hired-Hand Mega-Cool rev 6-09 User Manual
Page 37

Part No. 4801-5120 Rev. 6-09
Mega-Cool System
Page 37
Flush System – Sump Pump (Center
Mount Systems 10' - 80')
It is very important to flush the system. After completing
system assembly, follow steps below in order to flush out
debris from pipes.
1. Open ball valves at both ends of system. See diagram
above.
2. Turn on water. Fill reservoir to fill line.
3. Turn on sump pump to flush out system.
4. After flushing system, turn off sump pump.
5. Close ball valves at ends of spray line.
6. Close spray line above filter.
7. Clean
filter.
8. Open spray line.
9. Resume normal operation.
Drain
Filter
Ground
Level
NOTES:
1. Expect about 70 gallons of water per 50
feet of reservoir pipe.
Spray Line Cutoff Valve
Mega-Cool 10 ft. – 80 ft. Sump
Pump Flush System
Ball Valve
Ball Valve
Front View
Reservoir and Pump
Float
Assembly
NOTE: Pads removed for
clarity.