Hired-Hand Farm Hand Series: Heat Sink Grounding Instructions User Manual

Heat sink grounding instructions, Farm hand stage master, Farm hand swine finisher

Advertising
background image

Heat Sink Grounding Instructions

for

Farm Hand Stage Master

or

Farm Hand Swine Finisher

HIRED-HAND MFG., INC.

• 1733 County Road 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 256-287-2000

Manual Part No. 4802-5089 rev 04-04 Page

1 of 1






























DESCRIPTION

This instruction sheet provides information and photos to
correctly ground the circuit board heat sink during board
replacement of the Farm-Hand Stage Master or Swine
Finisher.

Tools Required

Philips Screwdriver

Nut-Driver Set

Needle Nose Pliers

HEAT SINK GROUNDING
INSTRUCTIONS

1. Ensure All Power Is Removed From Connections

And The Power Cord Is Unplugged.

2. Install the Ground screw from the inside of the

enclosure through the Triac and heat sink. Refer to
Figure 1 and IMPORTANT NOTES.

3. Place the Ground wire spade terminal between the

screw head and the Triac tab.

4. Install the Ground nut to the Ground screw on the

outside of the heat sink and tighten securely. Refer
to Figure 2.

HEAT SINK GROUNDING COMPLETE!

Replacement Numbers

Part Number

Model

Part Number

Model

Replacement Boards

6407-1313

PCB 150 12S

6407-1331

PCB 150 8S

6407-1309

PCB 145 SF

Controllers

6607-1551 FH-S5-S-1

6607-1516

FH-S5-S-2

6607-1526

FH-SM12-S-2

6607-1536

FH-SM08-S-2

DANGER

HAZARDOUS VOLTAGES

Failure To Follow These Instructions May Result in Injury
Or Death!
• Only A Certified Electrician Should Replace Circuit

Boards Assemblies.

• Do Not Perform Maintenance Without First

Removing All Power And Unplugging The Power
Cord.

!

NEW UT 1018 Module

Ground Nut

Heat Sink

FIGURE 2: Heat Sink

(Outside View)

PCB Ground

Wire

Spade

Terminal

Ground Screw

Triac

FIGURE 1: Replacement Circuit Board

(Inside View Example)

NOTE: PCB Ground Wire Made Available After 4/09/2004.

IMPORTANT!

1. Place the Spade

Terminal between the
screw head and the
Triac tab as shown.

2. DO

NOT place the Spade

Terminal between the
Triac tab and heat sink.

3. Ensure the Triac is

completely flush against
the heat sink.