Hired-Hand Farm Hand Series: Stage Master User Manual

Page 7

Advertising
background image

Part No. 4801-0151 Rev 4-06

Farm Hand Stage Master

7 of 40

Stages

Press any
stage
button to set
On/O ffPoints.

Adjust value
with + and -
buttons.

Stage Button





Target Temperature

The temperature the system tries to maintain.
To adjust these settings, press the mode button until you see the setting you want to
adjust, then use the + button to raise the value, and the - button to lower the value. When
you are finished setting a new value, either press the mode button again, or do nothing,
and the system will return to normal operation within a few seconds.

5.2

Running Curtain Machines

Under normal circumstances the machines should be left in automatic. This way, if the controller
needs to open the curtains, it will open them. If, however, you want to open or close them for any
reason do the following.
1. Find the switches for the machine you want to run, and check that the Open/Off/Close switch

is in the off position. This makes sure that the machine does not turn until you want it to.

2. Place the Automatic/Manual switch for that machine in the “Manual” position.
3. To open the machine place the Open/Off/Close switch to the position marked “Open”.
4. To close the machine place the Open/Off/Close switch to the position marked “Close”.
5. Finally when you are finished positioning the machine, place the switch back into the “Off”

position. Note: "Off" position is between "Open" and "Close".

6. When you are ready for the controller to take over control of the curtain, place the

Automatic/Manual switch in the automatic position.

5.3

Adjusting Stage On/OffPoints

If you decide that a fan stage comes on too
soon, or waits until temperature is too high to
come on, you can easily adjust that setting.
To adjust the stage OnPoint, press the
numbered stage button one time. The
individual stage display will flash, and the
main display will flash between “On” and the
Target Temperature. Use the + button to
raise the value in the individual stage display
until you see the correct temperature, or the -
button to lower the value until the stage
OnPoint is where you want it. When you are
finished setting a new value, press the
individual stage button again and the main
display will read “Off” and flash the target

Variable Speed Model

(Parameter selection sequence)