Warnings and safety rules, Location parts description – KuulAire PACKA53 User Manual

Page 4

Advertising
background image

To obtain a current list of Replacement Parts, visit us online at www.port-a-coolparts.com.

WARNINGS AND SAFETY RULES

!

LOCATION

PARTS DESCRIPTION

ELECTRICAL

ASSEMBLY INSTRUCTIONS

WARRANTY

CLEANING AND MAINTENANCE

TECHNICAL SPECIFICATIONS

TROUBLESHOOTING

REMOTE CONTROL

USE AND OPERATION

!

Symptom

Possible Cause

Possible Solution

No discharge of air

Cord is not plugged in

Make sure cord is plugged in and try to turn the unit on pressing

POWER button on control panel and remote control.

Power is not on

Check the circuit breaker or check

Circuit breaker/GFCI

GFCI reset button.

Not cooling

Water flow regulator at MIN setting Change the water regulator setting to MAX.

Low/No water

Check Water

Odor emission

Brand new unit

Brand new cooling pad will initially have an odor which will dissipate

within a week of initial use.

Old unit with algae

If the unit is not new, there may be an algae issue

– replace the pad and maintain regularly.

Water droplets coming

Calcium saturated water

Drain water, deep clean and clean the cooling pad.

out of air outlet

Cooling pad installed wrong

Adjust pad in back and install pad securely in place.

Clogged cooling pad

Cooling pad may need to be replaced.

The unit will not respond

Damaged PCB

Try with remote control. If the unit responds, PCB board fasteners

loose. If neither control panel nor remote control command works,

PCB board damaged - contact service technician.

Moisture in PCB

Try using remote control to see if the unit responds. If the unit

responds briefly, likely cause is the moisture in the PCB. Turn off

unit by unplugging it from the power. Drain, clean and dry the unit,

possibly replace the pad. Refill it with fresh water.

Remote control batteries

Check Batteries

Unit is making noise

Calcium build up in blower

Deep clean the unit -remove calcium debris.

Loose pump impeller cover

Securely fasten the impeller cover in the reservoir

Water Flow Regulator knob is at Close the water distribution compartment cover.

MIN position and the water

distribution compartment cover

is open

The unit will not

Damaged PCB

Damaged PCB - contact service technician.

turn off

Remote Control Batteries

Check batteries

1. Control Panel
2. Water Flow Regulator Knob
3. Water Level Gauge
4. Rear Cover
5. Water Fill Door
6. Base
7. Drain
8. Cord Wrap
9. Casters

WARNINGS AND SAFETY RULES

!

LOCATION

PARTS DESCRIPTION

ELECTRICAL

ASSEMBLY INSTRUCTIONS

WARRANTY

CLEANING AND MAINTENANCE

TECHNICAL SPECIFICATIONS

TROUBLESHOOTING

REMOTE CONTROL

USE AND OPERATION

!

Advertising