CHARGING THE BATTERY

When you charge, jump, replace, or otherwise connect battery
cables to the battery, be sure the polarity is correct. Improper
polarity can damage the charging circuit. The AIR VANTAGE®
500 positive (+) battery terminal has a red terminal cover.

If you need to charge the battery with an external charger,
disconnect the negative cable first, then the positive cable before
you attach the charger leads. After the battery is charged,
reconnect the positive battery cable first and the negative cable
last. Failure to do so can result in damage to the internal charger

components.

Follow the instructions of the battery charger manufacturer for
proper charger settings and charging time.

NAMEPLATES / WARNING DECALS
MAINTENANCE

Whenever routine maintenance is performed on this machine - or
at least yearly - inspect all nameplates and labels for legibility.
Replace those which are no longer clear. Refer to the parts list for
the replacement item number.

WELDER / GENERATOR
MAINTENANCE

STORAGE

Store the AIR VANTAGE® in a clean, dry protected areas.

CLEANING

Blow out the generator and controls periodically with low pressure
air. Do this at least once a week in particularly dirty areas.

BRUSH REMOVAL AND REPLACEMENT

It is normal for the brushes and slip rings to wear and darken
slightly. Inspect the brushes when a generator overhaul is
necessary.

Do not attempt to polish slip rings while the engine is
running.

--------------------------------------------------------------------------------------

GFCI RECEPTACLE TESTING AND RESETTING
PROCEDURE

The GFCI receptacle should be properly tested at least once
every month or whenever it is tripped. To properly test and reset
the GFCI receptacle:

• If the receptacle has tripped, first carefully remove any load and

check it for damage.

• If the equipment has been shut down, it must be restarted.
• The equipment needs to be operating at high idle speed and

any necessary adjustments made on the control panel so that
the equipment is providing at least 80 volts to the receptacle
input terminals.

• The circuit breaker for this receptacle must not be tripped.

Reset if necessary.

• Push the "Reset" button located on the GFCI receptacle. This

will assure normal GFCI operation.

• Plug a night-light (with an "ON/OFF" switch) or other product

(such as a lamp) into the GFCI receptacle and turn the product
"ON".

• Push the "Test" button located on the GFCI receptacle. The

night-light or other product should go "OFF".

• Push the "Reset" button, again. The light or other product

should go "ON" again.

If the light or other product remains "ON" when the "Test" button
is pushed, the GFCI is not working properly or has been
incorrectly installed (miswired). If your GFCI is not working
properly, contact a qualified, certified electrician who can assess
the situation, rewire the GFCI if necessary or replace the device.

Table D.1 Engine Maintenance Components

ITEM

MAKE

PART NUMBER

SERVICE INTERVAL

Air Cleaner Element

Donaldson

P822768

Replace as indicated by

Service Indicator

Fleetguard

AF25436

Oil Filer

Cummins

C6002112110

Replace every 750 hours or 3 months,

Fleetguard

LF16011

whichever is less.

Fan Belt

Cummins

C0412021749

Inspect every 1000 hours or 12 months,

whichever is less.

Fuel Strainer

Cummins

3826094

Inspect and replace monthly as

Fleetguard

FF5079

required. Replace annually.

Fuel Filter /

Fleetguard

FS19594

Replace every 500 hours or 6 months,

Water Separator

whichever is less.

.

Battery

-----

BCI GROUP 34

Inspect every 500 hours

Engine Oil Change

See Manual

-----

Change every 750 hours or 3 months,

whichever is less. Check daily.

D-4

MAINTENANCE

D-4

AIR VANTAGE® 500 CUMMINS