Installation – Lincoln Electric IM763 Commander 500 User Manual

Page 17

Advertising
background image

A-9

INSTALLATION

COMMANDER 500

A-9

CONNECTION OF AN LN-23P

WIRE

FEEDER TO THE COMMANDER 500

Shut the welder off.

Connect the LN-23P per instructions on the appro-

priate connection diagram in the DIAGRAMS sec-
tion. (NOTE): When connecting an LN-23P to the
Commander 500, a K350-1 adapter kit must be
used.

Set the

WIRE FEEDER VOLTMETER

switch to

-

.

Set the

SELECTOR

switch to

CV-WIRE

position.

Set the

WELDING TERMINALS

switch to

REMOTELY CONTROLLED

.

Set the ARC CONTROL to desired crispness. SOFT

for MIG - CRISP for Innershield.

If you are using an LN-23P with the K350-1 adapter

kit, the electrode is not energized until the gun trig-
ger is closed.

CONNECTION OF AN NA-3 AUTOMATIC
WELDING SYSTEM TO THE COMMANDER
500

For connection diagrams and instructions for connect-
ing an NA-3 Welding System to the Commander 500,
refer to the NA-3 Welding System instruction manual.
The connection diagram for the LN-8 can be used for
connecting the NA-3.

CONNECTION OF AN LN-742 TO THE
COMMANDER 500

Shut the welder off.

Connect the LN-742 per instructions on the appro-

priate connection diagram in the DIAGRAMS sec-
tion.

Set the

WIRE FEEDER VOLTMETER

switch to

either

+

or

-

as required by the electrode being

used.

Set the

SELECTOR

switch to the

CV-WIRE

posi-

tion.

Adjust the

ARC CONTROL

knob to desired

Crispness. SOFT for MIG and CRISP for Innershield.

Set the

WELDING TERMINALS

switch to the

REMOTELY CONTROLLED

position.

Advertising