Operation, Caution – Lincoln Electric IM830 EAGLE 10,000 User Manual

Page 18

Advertising
background image

RANGE” SWITCH

Never change the “RANGE” Switch setting while
welding. This will damage the switch.
------------------------------------------------------------------------

CONTROL” DIAL

Provides a fine welding current adjustment within the
Range Switch settings.

B-2

OPERATION

B-2

EAGLE 10,000

CAUTION

KOHLER

20 H.P. COMMAND

.39 Gallons/Hour

(1.49 Liters/Hour)

.74 Gallons/Hour

(2.79 Liters/Hour)

1.22 Gallons/Hour

(4.63 Liters/Hour)

1.29 Gallons/Hour

(4.87 Liters/Hour)

1.18 Gallons/Hour

(4.48 Liters/Hour)

1.40 Gallons/Hour)

(5.31 Liters/Hour)

Low Idle - No Load

2200 RPM

High Idle - No Load
3700 RPM
AC CC Weld Output
225 Amps @ 25 Volts
DC CC Weld Output
210 Amps @ 25 Volts
DC CV Weld Output
200 Amps @ 20 Volts
Auxiliary Power
9000 Watts

EAGLE 10,000 APPROXIMATE FUEL CONSUMPTION

Process Range Setting Current Range

STICK/TIG

(constant current)
(3 range settings)

90 Max.

145 Max.
210 Max.

50 to 90 Amps

70 to 145 Amps

120 to 210 Amps

Advertising