Installation, Gun cable connection to feeder – Lincoln Electric IM677 RED-D-ARC LN-25 User Manual

Page 10

Advertising
background image

LN-25

A-3

A-3

c. Set ELECTRODE POLARITY switch to constant

voltage polarity required by electrode.

d. Set toggle switch to “Constant Voltage” and set

the Constant Voltage Control on welder and the
portable field control on #5 for initial start.

SA-200, —250 OR SAE-300, —400 (WITH
CV ADAPTER)

a. For electrode negative welding, connect the

electrode lead from the LN-25 to the output
terminal on the CV Adapter, and the work lead to
the power source output terminal labeled
“POSITIVE”. For electrode positive welding,
interchange the above lead connections so the
LN-25 electrode lead is then connected to the
positive power source terminal.

b. Place both switches on the CV Adapter to the CV

INNERSHIELD position and make appropriate
power source settings per the CV Adapter instruc-
tions provided for the power source being used.

c. The output voltage is set with the voltage control

on the CV Adapter.

NOTE: Refer to the Instruction Manual provided with
the machine for details on connection and operation
of the LN-25 with the power source.

INVERTEC, CV300 AND OTHER NEWER
LINCOLN POWER SOURCES

Refer to the instruction manual provided with the
power source for details on connection and operation
of the LN-25 with these newer machines.

GUN CABLE CONNECTION
TO FEEDER

Lay the cable out straight. Insert the connector on the
welding conductor cable into the brass conductor block
on the front of the wire drive unit. Make sure it is all the
way in and tighten the hand wheel clamp. Keep this
connection clean and bright. Connect the control cable
polarized amphenol plug into the mating 5-cavity
receptacle on the front panel of the wire feeder case.

FOR GMA GUN AND CABLES:

Requires installation of K430-1 Gas Solenoid Kit
(factory installed on K446 and K449 models).

See K430-1 Gas Solenoid Kit Section (in Accessories
Section) for gas solenoid operation and gas supply
connection.

c. Place “Set to Same Polarity As Electrode Cable

Connection” switch at appropriate position.

d. Place power source toggle switch in “Output

Control at DC(CV) -400” position, unless a remote
control is connected to 75, 76 and 77 on the
power source terminal strip.

e. If power source has a mode switch, set switch to

Constant Voltage Innershield. Initially set the
output control on “6”.

DC-600

a. Connect a jumper from 2 to 4 on the power source

terminal strip so the output will be energized when
the DC-600 is turned on. (For DC-600 below Code
8200, also jumper N to S.)

b. Connect the electrode cable to the output terminal

of polarity required by electrode. Connect work
lead to other output terminal.

c. Place “Set to Same Polarity As Electrode Cable

Connection” switch at appropriate position.

d. Place power source toggle switch in “Output

Control at DC-600” position, unless a remote
control is connected to 75, 76 and 77 on the DC-
600 terminal strip.

e. Set mode switch to Constant Voltage Innershield.

Initially set output control on “4”.

R3S-325

a. Connect a jumper from 4 to 32 on the power

source terminal strip so that the output will be
energized when the R3S-325 is turned on.

b. Connect the electrode cable to the output terminal

of polarity required by electrode. Connect work
lead to other output terminal.

c. Set power source per its instruction manual.

NOTE:

Use of the optional Line Voltage

Compensator available for the R3S-325 is
recommended if input line voltage variation
exceeds ±3%.

SAM-400, —650

a. Connect a jumper from 2 to C4 on the power

source terminal strip so the output will be
energized when the SAM power source is on.

b. Connect work lead to WORK stud. Connect

electrode to AUTO EQUIPMENT stud. Connect
SAM-650 “Tap” lead to the Innershield stud
desired.