Maintenance, Calibration of ln-25 wire speed dial, Warning – Lincoln Electric IM677 RED-D-ARC LN-25 User Manual

Page 24

Advertising
background image

LN-25

D-2

D-2

The module is properly mounted to the gearbox
as shipped from the factory. If the device is ever
removed or replaced, proper mounting technique is
as follows:

1. Be sure all power to the LN-25 is shut off at the

power source.

2. Check that the module mounting plate is screwed

securely to the side of the gearbox.

3. Gently screw the module into the mounting plate

until it

just

touches and stops against the

rotating part inside the gearbox.

4. Back the module out

1

2

turn, then snug the

module lock nut without rotating the module
position. Do not over tighten lock nut.

CALIBRATION OF LN-25 WIRE
SPEED DIAL

Calibration of the LN-25 Wire Speed dial is achieved
by proper mounting of the dial knob to the speed
potentiometer shaft. Whenever the knob is removed,
the dial is recalibrated as follows:

NOTE:

Knob set screw does

not

seat on shaft flat.

1. Be sure the Wire Speed potentiometer mounting

nut is securely tightened, then rotate the
potentiometer shaft so its flat faces about to the
100 mark on the LO range calibrated dial.

2. Set DIAL RANGE switch to LO and WIRE FEED

MODE switch to CV position.

3. Press gun trigger to feed wire and measure

the wire feed speed (IN/MIN) using a Portable
Digital Wire Feed Speed Meter (Lincoln K283).
Take at least two readings to assure repeat-
able accuracy.

Feed Speed Meter (Lincoln K283). Take at least
two readings to assure repeatable accuracy.

Electrode will be electrically

hot

. Do not allow

fed wire to touch your body or contact any metal
common with welding work.

--------------------------------------------------------------------

An alternate means to measure wire feed speed
is as follows:

a. Cut wire off at the end of the gun tip.

b. Press trigger to feed wire for exactly 30 seconds.

c. Cut fed wire off at the end of the gun tip and

accurately measure its length.

d. Multiply the measured length by 2 to obtain

the wire speed (IN/MIN).

e. Repeat above steps to assure repeatable

accuracy.

4. Carefully slip speed knob onto potentiometer

shaft so it points precisely to the wire speed
measured in step 3, then secure the knob set
screw without disturbing the position. Recheck by
repeating step 3.