Lincoln Electric IM408 MAGNUM SG SPOOL GUN User Manual
Page 12
![background image](/manuals/363487/12/background.png)
SPOOL GUN
GUN CABLE
ADAPTER CABLE
CONTROL CIRCUIT DIAGRAM (ABOVE CODE 9100) FOR SP-150
6. Connect spool gun power cable to (+) stud
terminal on SP-150. Disconnect any lead
already attached there.
7. Connect work lead to (–) stud terminal on
SP-150 if not already connected there. Close
left side door.
9. Connect regulated argon gas supply to gas
inlet fitting on rear panel of SP-150.
8. On front control panel of SP-150:
8A. Connect spool gun gas line to gas outlet
fitting.
8B. Set welding voltage.
(1)
8C. Set wire feed speed.
(1)
(1)
See Part B, “Test Weld Settings".
5
NOTE: Connector pinouts show view of mating connector sides.
NOTE: Connector pinouts show view of mating connector sides.
SPOOL GUN
GUN CABLE
ADAPTER CABLE & WIRES
CONTROL CIRCUIT DIAGRAM (BELOW CODE 9100) FOR SP-150