Installation, A-6 configuring the system, Up to 4 feeders allowed up to 4 feed heads allowed – Lincoln Electric IM807 POWER WAVE 455M User Manual

Page 16

Advertising
background image

A-6

INSTALLATION

POWER WAVE 455M (CE)

A-6

CONFIGURING THE SYSTEM

For codes below 11100, consult the semi-automatic
Power Feed instruction manual for configuration infor-
mation about DIP switch settings.

For codes above 11100 the power source will

Auto

Map

the system eliminating most of the need to set

DIP switches to configure the system.

If a system can not be

Auto Mapped

then the status

light on the power source will blink green fast and the
welder output will be disabled. If a system is not

Auto-mappable

, then consult the instruction manual

for the accessory being used for configuration infor-
mation about DIP switch settings, or consult your local
Lincoln sales representative.

POWER WAVE

455M(CE)

ROBOT

PLC CONTROLLER

ANALOG INTERFACE

etc.

POWER WAVE 455M(CE)

POWER WAVE

455M(CE)

POWER WAVE

455M(CE)

FEED HEAD

SINGLE HEAD FEEDER

DUAL HEAD FEEDER

SINGLE HEAD BOOM FEEDER

FH 1

PF-10R

Typical Robotic/ Hard Automation
(using Wire Drive Module and PF-10R)

UP TO 4 FEEDERS
ALLOWED

UP TO 4 FEED HEADS
ALLOWED

WIRE
DRIVE
MODULE