Troubleshooting, Caution wire drive module – Lincoln Electric IM986 POWER WAVE i400 User Manual

Page 41

Advertising
background image

LECO

(FANUC#)

129

130

131

132

E-4

TROUBLESHOOTING

E-4

POWER WAVE® i400

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

WIRE DRIVE MODULE

Observe all Safety Guidelines detailed throughout this manual

ERROR CODES FOR THE POWER WAVE®

The following is a partial list of possible error codes for the POWER WAVE® i400. For a complete listing consult
the Service Manual for this machine.

Error Code #

81 Motor Overload

82 Motor Overcurrent

83 Shutdown #1

84 Shutdown #2

Indication

Long term average motor current limit has been exceeded. Typically
indicates mechanical overload of system. If problem continues con-
sider higher torque gear ratio (lower speed range).

Absolute maximum motor current level has been exceeded. This is a
short term average to protect drive circuitry.

The Shutdown inputs on the POWER WAVE® i400 have been dis-
abled. The presence of these errors indicates the Feed Head Control
PCB may contain the wrong operating software.

Advertising