Installation, Technical specifications – pro-mig 140 – Lincoln Electric IM884 PRO-MIG 140 User Manual

Page 7

Advertising
background image

A-1

Pro-MIG 140

A-1

Fuse or

Output Mode

Input Voltage

Breaker Size

1

Input Amps

Power Cord

Extension Cord

Three Conductor

#14 AWG

(2.1 mm

2

) or Larger

RATED

120V/60Hz

20 Amp

20

15 Amp, 125V,

Up to 25 Ft. (7.6 mm)

Three Prong Plug

Three Conductor

(NEMA Type 5-15P)

#12 AWG

(3.3 mm

2

) or Larger

Up to 50 Ft. (15.2 mm)

INSTALLATION

TECHNICAL SPECIFICATIONS – Pro-MIG 140

INPUT – SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT CABLE AND FUSE SIZES

Height

Width

Depth

Weight

12.0 in

9.75 in

16.5 in

48 Ibs

305 mm

248 mm

419 mm

21.8 kg

PHYSICAL DIMENSIONS

Standard Voltage/Frequency

Input Current

120V/60Hz

20 Amps - Rated Output

Duty Cycle

Current

Voltage

20% Duty Cycle

90 Amps

19 V

Welding Current Range

Maximum-Open Circuit Voltage

Wire Speed Range

25-140 Amps

29V

50 - 300 in/min.

(1.3 - 7.6 m/min.)

1

If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.