Troubleshooting, Caution – Lincoln Electric IM862 VANTAGE 500 DEUTZ User Manual

Page 36

Advertising
background image

E-4

TROUBLESHOOTING

E-4

VANTAGE 500 DEUTZ

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Engine goes to low idle but does not
stay at low idle.

No welding output or auxiliary out-
put.

Welder has some/ no output and no
control. Auxiliary output OK

No welding output. Auxiliary output
OK.

No auxiliary power.

1.

Faulty Peripheral PCB,
Idler/Engine Protection PCB or
Weld Control PCB.

1. Broken lead in rotor circuit.
2. Faulty field diode module.
3. Faulty Weld Control PCB.
4. Faulty rotor.

1. Faulty remote kit.
2. Faulty output control potentiome-

ter.

3. Faulty output control wiring.
4.

Faulty Weld Control PCB,
Idler/Engine Protection PCB or
Chopper PCB.

1. WELDING TERMINALS switch in

wrong position, be sure switch is
in WELDING TERMINALS
ALWAYS ON position.

2.

Faulty Weld Control PCB,
Idler/Engine Protection PCB or
Chopper PCB.

1. Open breakers may need to be

reset.

2. Faulty receptacle.
3. Faulty auxiliary circuit wiring.
4. GFCI tripped.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.

FUNCTION PROBLEMS

Advertising