ACTUATOR PLUNGER SERVICING

To service the actuator plunger first

shut off the compressed air supply,

bleed the pressure from the pump, and

disconnect the air supply line from

the pump.

Step #1: See PUMP ASSEMBLY

DRAWING.

Using a 1/2" wrench or socket,

remove the four capscrews (items

11). Remove the air inlet cap (item

8) and air inlet gasket (item 18). The

pilot valve assembly (item 4) can now

be removed.

Step #2: Inspect the actuator

plungers.

See ILLUSTRATION AT RIGHT.

The actuator plungers (items 30)

can be reached through the pilot valve

cavity in the intermediate assembly

(item 5).

Remove the plungers (item 30) from

the bushings (item 7) in each end of the

cavity. Inspect the installed o-ring (items

26) for cuts and/or wear. Replace the

o-rings if necessary. Apply a light

coating of grease to each o-ring and

re-install the plungers in to the

bushings. Push the plungers in as far as

they will go.

To remove the bushings (item 7),

first remove the retaining rings (item 31)

by using a flat screwdriver.

NOTE: It is

recommended that new retaining rings

be installed.

Step #3: Re-install the pilot valve

assembly into the intermediate assembly.

Be careful to align the ends of

the stem between the plungers when

inserting the stem of the pilot valve into

the cavity of the intermediate.

Re-install the gasket (item 18),

air inlet cap (item 8) and capscrews

(item 11).

Connect the air supply to the pump.

The pump is now ready for operation.

ACTUATOR PLUNGER DRAWING

33

30

5

31

7

26

Read these instructions

completely, before

i n s t a l l a t i o n a n d

start-up. It is the

responsibility of the

purchaser to retain this

manual for reference. Failure to comply

with the recommendations stated in this

manual will damage the pump, and void

factory warranty.

IMPORTANT

Advertising