m15mdl1sm-rev0713

Model M15 Metallic Page 29

This 8 foot long (244 centimeters) Ground Strap,

part number 920-025-000, can be ordered as a

service part.

To reduce the risk of static electrical sparking,

this pump must be grounded. Check the local

electrical code for detailed grounding instruction

and the type of equipment required.

Grounding The Pump

Take action to prevent static

sparking. Fire or explosion can

result, especially when handling

flammable liquids. The pump,

piping, valves, containers or other

miscellaneous equipment must

be grounded.

WARNING

One eyelet is installed to a true earth ground.

(Requires a maximum 5/16 or 8mm diameter bolt)

One eyelet is fastened to the pump hardware.

To be fully groundable, the pumps must be ATEX

Compliant. Refer to pump data sheet for ordering.