Specifications-indoor dome, Operational, Specifications-sdu vii – American Dynamics RAS915 User Manual

Page 10

Advertising
background image

SPEEDDOME ULTRA VII CAMERA DOME CONFIGURATION UTILITY

8200-0184-09, REV. A

OPERATOR’S MANUAL SUPPLEMENT

10 of 13

5. Use the joystick to move the highlight to

Presets. Press Set to select. The Select
Preset to Program
screen displays.

SELECT PRESET TO PROGRAM

PRESET

NUMBER

PRESET NAME

1-96

PRESET 1-96

FOCUS FAR to program preset

EXIT

6. Use the joystick to select the Preset you want

to program. If the Preset has been
programmed the dome automatically moves to
that position.

Move the joystick right to increase the

preset number.

Move the joystick left to decrease the

preset number.

When the correct Preset number appears,
press Set to begin programming.

7. The

Presets screen displays. Use the joystick

to adjust the dome to the correct pan/tilt
position.

PRESETS

PRESET X

Position camera with PAN

TILT, ZOOM and IRIS

FOCUS FAR to save and exit

EXIT

IMPORTANT!

If using the WV-CU550A

Controller with the WJ-SX550 Multiplexer, you
must press F3 (A. Res) to adjust the zoom,
focus, or iris settings. This places the controller
in normal navigating mode. Make the
necessary adjustments. When finished, press
F1 (On) to resume menu mode.

8. Press

Set to save the Preset information.

9. To program more Presets, repeat steps 5

through 8. To exit the Dome Configuration
Menu
and save changes, press F4 (Exit).

To verify the Preset programming, enter a Preset
number (1-64) and press Preset.

Specifications-Indoor Dome

Operational

Pan/Tilt:

Manual Pan Speed......................... 0.2°-100° per second

(scaled to zoom position)

Manual Tilt Speed ........................ 0.25°-100° per second

(scaled to zoom position)

Preset Pan/Tilt Speed ............220° per second maximum

Pan Travel..................................360° continuous rotation

Tilt Travel ..................................................................>90°

Pan/Tilt Accuracy .....................................................±0.5°

22X Camera Zoom Functions:

Optical Zoom..............................................................22X

Digital Zoom ...............................................................11X

Zoom Pause......................................... 22X selectable or
33X

default

Total Zoom ...............................................................242X

Maximum Zoom Stop .......44X, 66X, 88X (default), 110X,

132X, 154X, 176X, 198X, 220X, 242X

Zoom/Focus Accuracy ........................................... ±0.5%

23x Day/Night

Camera Zoom Functions:

Optical Zoom..............................................................23X

Digital Zoom ...............................................................10X

Zoom Pause......................................... 23X selectable or
35X

default

Total Zoom ...............................................................230X

Maximum Zoom Stop .......46X, 69X, 92X (default), 115X,

138X, 161X, 184X, 207X, 230X

Zoom/Focus Accuracy ........................................... ±0.5%

Auto Synchronization:

Line Locked.........................Remote V-phase adjustment

Internal ..........................................Built-in sync generator

Address Range ....................................................... 1-255

Number of Presets:

VM16 / ADTT16 ........................... 96 with SensorNet 485

VM32 / AD32................................ 96 with SensorNet 485

AD2150 ............................................. 64 with Manchester

16 with RS422 (using AD2083-02A)

VM96......................Virtual with RS422 or SensorNet 485

VM168 / AD168................................ 64 with Manchester,

RS-422 or SensorNet

16 with RS422 (using AD2083-02A)

AD2050 ............................................. 64 with Manchester

16 with RS422 (using AD2083-02A)

Advertising