Changing the auto iris/auto focus resume setting, Scan limits – American Dynamics RAS915 User Manual

Page 4

Advertising
background image

SPEEDDOME ULTRA VII CAMERA DOME CONFIGURATION UTILITY

8200-0184-09, REV. A

OPERATOR’S MANUAL SUPPLEMENT

4 of 13

Changing the Auto Iris/Auto
Focus Resume Setting

Refer to the SpeedDome Ultra VII Operator’s
Manual for information about displaying menus and
changing settings.

1. Select

Pan/Tilt/Zoom/Sync Opts from the

Dome Configuration Menu.

2. Move the highlight bar to I/F Return to Auto.

Change the setting.

• Select On to enable both resume auto iris

and resume auto focus.

• Select Off to disable both resume auto iris

and resume auto focus.

• Select Iris to enable resume auto iris only.

• Select Focus to enable resume auto focus

only.

The default setting is On.

3. Select

Exit to return to the Dome Configuration

Menu.

Scan Limits

Scan Limits are two points around the dome’s pan
axis, which define a surveillance area. When
active, the scan repeats until interrupted by a
camera command, preset, pattern, or alarm.

Figure 4 provides an example of scan limits for a
dome installed over the edge of a building
monitoring a parking lot. In this example, the
building blocks part of the dome’s viewable area.

Figure 4: Scan Limits example

The dashed circle represents the dome’s field of
view. The solid line curve represents the scan
area. By setting the left and right scan limits where
the building’s wall becomes visible, you ensure that
only useful video of the parking lot is being
observed when the scan is active. Once these
scan limits are programmed you can choose to run
a smooth scan, stepped scan, or random scan.

Table 2: Scan Types

Smooth Scan

An automated scan that slowly
pans between the left and right
scan limits, starting at the left
scan limit. When the right scan
limit is reached, the scan
reverses.

Stepped Scan

An automated scan that pans
slowly pausing briefly every 10°
between the left and right scan
limits. Once the right scan limit
is reached, the scan reverses.

Random Scan

An automated scan that pans
randomly between the left and
right scan limits, starting at any
point between the scan limits.

If your controller supports the Quick Set menu
function, you can program left and right scan limits
to automate your surveillance activities. The Scan
Limits
menu option is found on the Alarms/Areas/
Home/Presets/PZ
menu.

Figure 5: Alarms/Areas/Home/Presets/Privacy
Zones menu

ALARMS/AREAS/HOME/PRESETS/PZ

SET ALARM ACTIONS

SET ALARM STATES

SET HOME POSITION

SET NORTH POSITION

AREA BOUNDARIES

PRIVACY ZONES

PRESETS

SCAN LIMITS

EXIT

Continue with Programming Scan Limits on page 5
to configure the setting.

Left Scan

Limit

Right Scan

Limit

Dome

Buildi

ng

Advertising
This manual is related to the following products: