Air conditioner features – SoleusAir SG-TTW-12ESEZ-26 User Manual

Page 15

Advertising
background image

Air Conditioner Features

(continued)

HEATING FEATURE

(on some models)

:

YOU WILL SEE:

If the display reads “F1”

a sensor has failed.

If the display reads “F2”

a sensor has failed.

If the display reads “F4”

a sensor has failed.

If the display reads “FJ”

a sensor has failed.

DO THIS:

PRESS

MODE BUTTON

SELECT HEAT

Note: This feature can be used with any combination of FAN Speeds, Timer, or Sleep Modes. When in the “Heat” Mode, the

fan will run continuously while heat is needed. The temperature will automatically be maintained anywhere between 61°F

(16°C) and 86°F (30°C). When the set room temperature is reached, the fan will cycle off and on to circulate and sample

the room air.

FAULT CODES

SLEEP FEATURE : YOU WILL SEE

DO THIS:

:

PRESS

MODE BUTTON

SELECT SLEEP

Note: Press this button, Sleep On and Sleep Off can be selected. When the unit is on,Sleep Off is defaulted. After the unit is shut

off, the Sleep function is canceled. If the

unit is in Cool or Energy Saver Modes, and the Sleep Mode is set, the SET TEMP. will

increase 2*F in 1 hour and 4*F in 2 hours. If the unit is in Heat Mode, and Sleep Mode is set, the SET TEMP. would decrease 2*F

in 1 hour and 4*F in 2 hours.

TO TURN UNIT OFF: YOU WILL SEE:

DO THIS:

PRESS

ON/OFF BUTTOT

12

Advertising
This manual is related to the following products: