INSTALLATION INSTRUCTIONS

MODEL COND-1 Condensate Pump

PREINSTALLATION CHECKLIST - ALL INSTALLATIONS

NOTICE TO INSTALLER: Instructions must remain with installation.

1. To help reduce the risk of electrical shock, a properly

grounded receptacle or control box of grounding type must

be installed and protected by a ground fault circuit interrupter

(GFCI) in accordance with the National Electrical Code and

applicable local codes. If pump is wired direct, a GFCI must

be installed in the control box. (SEE WARNING BELOW)

2. Make certain that the ground fault interrupter protected recep-

tacle or control box is within reach of the pump’s power supply

cord. DO NOT USE AN EXTENSION CORD. Extension cords

that are too long or too light do not deliver sufficient voltage

to the pump motor. But more important, they could present a

safety hazard if the insulation were to become damaged or

the connection end were to fall into a damp or wet area.

3. Make sure the pump's electrical supply circuit is equipped

with fuses or circuit breakers of proper capacity.

A separate

branch circuit, sized according to the National Electrical Code

1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before

using.

2. Carefully read all the literature provided to familiarize yourself with specific details regarding installation and use before attempting

the installation. These materials should be retained for future reference.

1. Check to be sure your power source is adequate to handle

the amperage requirements of the motor as indicated on the

pump or unit I.D. tag.

2. All plumbing (discharge and drain lines) must be installed to

meet local codes.

for the current shown on the pump name plate is recom-

mended.

4. TESTING FOR GROUND. As a safety measure, each electri-

cal outlet should be checked for ground using an Underwriters

Laboratory Listed circuit analyzer which will indicate if the power,

neutral and ground wires are correctly connected to your outlet.

If they are not, call a qualified licensed electrician.

5. Installation and checking of electrical circuits and hardware

should only be performed by a qualified licensed electrician.

6. FOR YOUR PROTECTION ALWAYS DISCONNECT PUMP

FROM ITS POWER SOURCE BEFORE HANDLING.

7. According to the state of California (Prop 65), this product

contains chemicals known to the state of California to cause

cancer and birth defects or other reproductive harm.

SEE BELOW FOR

LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

NOTE: Pumps with the “UL” mark and pumps with the “US” mark

are tested to UL Standard UL778. CSA Certified pumps are

certified to CSA Standard C22.2 No. 108.

SEE BELOW FOR

LIST OF WARNINGS