*** WARNING***
This unit may be equipped with more than one power
cord. DISCONNECT ALL POWER CORDS PRIOR
TO SERVICING!
POWER OUTLET
ACCESSIBILITY
Whether you are installing a new
outlet, or plan to use an existing
outlet to supply power to the ATM,
make sure the following require-
ments are met:
1. The outlet is located near the
cabinet.
2. The outlet is easily accessible.
3. Access to the outlet will not be
blocked once the cabinet is in-
stalled!
POWER SUPPLY CORD
SPECIFICATIONS
For European applications, the power
supply cord must conform to the fol-
lowing specifications:
1. Two-conductor with physical
earth ground.
2. IEC 320 molded connector on
one end and molded plug on the
other end.
3. Certified for country of
installation.
4. Rated minimum H05VV-F with
minimum 0.75 mm2 (except where
specific countries require 1.0
mm2) conductors.
5. Maximum length: 3 meters.