Storage / transport procedures, Caution – WEN 56100 Power Pro 2 Stroke 1000 Watt User Manual
Page 21

18
4. Using a pair of pliers, slide the fuel line clamp off the fuel valve so the line can be disconnected.
5. Collect any fuel left in the fuel line going to the carburetor.
6. Place the fuel tank over the fuel collecting container and open the fuel valve. The fuel should
drain from the tank.
7. Reconnect the fuel line and reattach the fuel tank with the four (4) bolts.
8 Start and run the engine until fuel runs out.
9. Store the emptied fuel in a suitable place.
CAUTION: Do not store fuel for more than 3 months.
STORAGE / TRANSPORT PROCEDURES
CAUTION:
Never place any type of storage cover on the generator
while it is still hot.
If the generator is being stored for short periods of time (30 – 60 days), add stabilized fuel to the
fuel tank until full. NOTE: Filling the tank reduces the amount of air in the tank and helps reduce
deterioration of fuel. Run the engine for 2 – 3 minutes allowing stabilized fuel mixture to
circulate through the carburetor.
When transporting or storing the generator for extended periods of time:
• Drain the fuel tank (see “Draining the Fuel Tank” in the “Maintenance” section).
• Disconnect the spark plug wire from the spark plug.
• Do not obstruct any ventilation openings.
• Keep the generator in a cool dry area.