Manual Start

To start your generator using the manual start function, perform the following steps:

1. No electrical devices should be connected to the generator during starting. Devices can

make it difficult for the engine to start.

2. Check that the generator is properly grounded (see Figure 11 “Ground the Generator”).
3. Check the oil and fuel levels.
4. Turn the fuel valve to the “ON” position (see figure 12).
5. Move the choke lever to the “START” position (see figure 13).
6. Set the engine switch to the “ON” position.
7. Pull on the recoil starter handle slowly until a slight resistance is felt. Then pull quickly to

start the engine. Return cord gently into the machine. Never allow the cord to snap back.

8. If engine fails to start, repeat step 7. NOTE: After repeated failed attempts to start the

engine, please consult the troubleshooting guide before attempting again. If problems
persist please call (800) 232-1195 M-F 8-5 CST.

9. Once the engine has started, slowly return the choke lever all the way to the “RUN”

position.