Shark tx/p ph, orp, conductivity, flow transmitter, Technical data – Aquametrix SHARK TX / TXP Transmitters Datasheet User Manual

Page 2

Advertising
background image

SHARK TX/P pH, ORP, Conductivity, Flow Transmitter

Technical Data

pH

ORP

Conductivity

Flow

Display

Front Panel: 4 x 7 segment 1/2” LED display, 1 LED indicator 0n-line,7 LED

Bar Graph. Inside Panel: 2 x 16 alpha-numeric LCD display

Measuring Range

pH: 0.01 to 14.00

Temp: 0 to 100°C

or 32° to 212°F

ORP: -1999 to +1999mV

(Dependent on sensor)

Temp: 0 to 100°C

or 32° to +212°F

MΩ/

cm

3

0 to 19.9

0.01

µS/

cm

3

0 to 2.00

0.01

0 to 20.0

0.1

0 to 200

0.1

0 to

2000

1.0

mS/

cm

3

0 to 20

10

0 to 200

50

Flow: 0 to 9999 with

selectable flow rate units

Volume: 0 to 9999 with

Auto Range Flow rate

units: Gallons (GP),

Cubic Feet (CF), Liters

(LP), Cubic Meters (CM),

custom by entering factor

related to Gallons.

Time units: Seconds (S),

Minutes (M), Hours (H)

Temperature

Compensation

Automatic or Manual

0 to 100°C (32° to +212°F)

Not required

Automatic or Manual

User selectable tempera-

ture compensation slope

0.0 to 10.0% / °C.

0 to 100°C (32° to 212°F)

Not required

Temperautre Unit

°C or °F

Not required

Temperature Sensor

User selectable: 300Ω NTC Thermistor, 3000Ω NTC Thermistor or Pt. 1000 RTD

Calibration modes

Auto-Calibration,

Manual Calibration,

Temperature Display

Manual Calibration

Temperature Calibration

Dry Calibration

Sample Calibration

Temperature Calibration

K factor input

Ambient Conditions

Temperature: -20°C to +60°C or -4°F to +140°F Humidity: 0 to 90% RH (non-condensing)

Sensor to Trans-

mitter Distance

Differential Sensor: 3000 ft

Combination Sensor:10 ft

300 ft

2000 ft

AnalogOutput

4 to 20 mA

Isolated Output, Range expand 0 to 100% of full scale (min segment 10% of full scale),max. load 800Ω

Memory Back-up

All user settings are retained indefinitely in memory (EEPROM)

Mechanical

SHARKTX Enclosure:NEMA 4X, 1/4 DIN, polycarbonate enclosure with two 1/2” conduit holes

SHARKTXP Enclosure:NEMA 4X front panel, 1/4 DIN, polycarbonate

SHARKTX Mounting: Universal Mounting kit for surface, pipe and panel mount included

SHARKTXP Mounting: Panel and DIN rail mount included

Sensor Input

Probe: -600 to +600 mV

Temp. Sensor: 0 to 9999 Ω

Probe: -1999 to

+1999 mV

Temp. Sensor:

0 to 9999 Ω

Cell: 0 to 9999 Ω

Temp. Sensor: 0 to 9999 Ω

Paddle: 0 to 2000 Hz

Invalid Entries

Invalid entries cannot be stored

Manual Test Mode

Process value can be simulated with arrow keys to verify correct setup of outputs

Output Hold

4 to 20 mA output is placed on hold when the transmitter is in Menu mode

Calibration Data

Recall data from last calibration, calibra-

tion mode, 1st&2nd accepted buffer value

and probe mV output, calibration tempera-

ture, calibration slope, and probe efficiency

Recall data from last calibra-

tion, calibration buffer ac-

cepted value and cell resistance,

calibration temperature.

Recall store K factor.

Auto Return

User selectable auto return if the transmitter is left in menu mode for more than 10 min.

Display Damping

User can select rate at which SHARK updates display. Enables display damping of unstable process

Net Weight

SHARK-TX: 0.71 lbs (0.32 kg)

SHARK-TXP: 0.25 lbs (0.12 kg)

www.WaterAnalytics.net

978-749-9949

888-749-9099