RT-30EX Flow Transmitter

Operation and Programming Manual

7

RT-30EX User Manual, Rev. 1.7 02/07/2012

Specifications

Power Requirements: 9-24 VDC/200mA, Class 2 (customer supplied)

Sensor/Monitor Input Ratings:

o Frequency Input Range: 0.3-4,500 Hz

o Sensor Supply Voltage: 12 VDC @ 50mA Max.

o Magnetic Sensor Input: 15mV

P-P

Min., 24V

PEAK

Max.

o High Level Pulse Input: 2V

PEAK

Min., 24V

PEAK

Max.

Analog Output 4-20 mA: 16-bit isolated loop powered 2-wire output; 9-24 VDC, Class 2 loop

supply; max. load impedance = 500 Ohm @ 24V; max. load impedance = 250 Ohm @ 12V

Three Opto-Isolated Open-Collector Outputs: 5-30 VDC, Class 2 rating, 40 mA Max.

(minimum load impedance required = 600 Ohm @ 24 VDC)

Opto-Isolated Reset Input: 12-24 VDC Input, Class 2, 3.3Kohm Impedance

Temperature Ratings: -4 to 140°F (-20 to 60°C) ambient; 185°F (85°C) max. fluid

temperature (standard); 350°F (175°C) max. fluid temperature with optional high

temperature pickup version.

Enclosure Certification: Type 4X

Connection: spring terminal strips; ¾" NPT conduit entrance

Display update rate: 250 milliseconds (4 times per second)

Analog output update rate: 20 milliseconds (if Gate Time filter off)