Figure #3, Figure #4 – Detcon FP-524HT User Manual

Page 10

Advertising
background image

There is a limit 0.5 ohm maximum resistance drop per wire over the seperation distance.

AWG

Maximum Seperation (feet)

20

50

18

75

16

125

14

175

Reference f igure 4 for wiring diagram. Also note the jumper that is required on the remote sensor connector board.

Failure to install this jumper will cause a sensor fault condition.

Remote Mounting Configuration - Bridge Voltage Adjustment

When a sensor is remote mounted, consideration must be given to the lengths of cable used and how it affects the

sensor bridge voltage. Differing lengths of cables will have varying amounts of resistance which will shift the sensor

bridge voltage. Because of this, the bridge voltage will need to be adjusted after initial power up. This adjustment is

only required after initial installation and will not be necessary thereafter, even in the event of replacement of the

plug-in sensor. See section 3.6.2 for instructions.

3.6 S

TART

U

P

Upon completion of all mechanical mounting and termination of all f ield wiring, apply system power and observe

the following normal conditions:

Model FP-524HT Combustible Gas Sensor PG.10

WHT

BLK

YEL

BLU

mA

VDC Power In

4-20 mA Output

To
Sensor

Base Connector Board

Blue wire

Empty

Green wire

Red wire

Figure #3

1 2 3 4

W

H

T

B

L

K

Y

E

L

B

LU

Install
Jumper

Remote Transmitter

FP-524C-RT

Remote Sensor

FP-524C-RS

Measure Bridge Voltage
From White (1) to Blue (4)
Target voltage is 2.7v

WHT

BLK

YEL

BLU

Plug unused port
with 3/4 NPT plug.

Figure #4