GW Instek SPS Series User Manual
Page 6

2
2. SPECIFICATION
2-1. General
Main supply
: 115V/230V±15% 50/60Hz (Switch selectable).
Rating, dimension and weight
: See Table 2-1.
Table 2-1
MAX. RATING
INPUT RATING
FUSE STYLE & RATING
WEIGHT
Model
Voltage
Current
Watts
VA
115V
230V
kg
SPS-1230
12V
30A
SPS-1820
18V
20A
SPS-2415
24V
15A
SPS-3610
36V
10A
SPS-606
60V
6A
500
900
T 10A 250V
T 6.3A 250V
3.3
Dimensions:128(W) × 145(H) × 285(D) mm.
WARNING: Voltage over 60V DC is a lethal shock hazard to the user. Be careful when
connecting power supplies in series to achieve voltage higher than 60V DC totally or 60V
DC between any connection and earth ground.
Operation Environment
: Indoor use,
Altitude up to 2000m,
Installation Category II,
Pollution degree 2.
Operation Temperature &Humidity : 0℃ to 40℃, <80%.
Storage Temperature & Humidity
: -10℃ to 70℃, <70%.
Accessories
: Test Lead (current < 4A)……………………………………………
× 1
Operation Manual..…………………………………………………………. Ч 1