Appendix, Psw default settings, Ppendix – GW Instek PSW-Series Programming & Command manual User Manual
Page 114

PSW Series Programming Manual
114
A
PPENDIX
PSW Default Settings
The following default settings are the factory configuration settings
for the power supply (Function settings/Test settings).
Initial Settings
Default Setting
Output
Off
LOCK
0 (Disabled)
Voltage
0V
Current
0A
OVP
Maximum
OCP
Maximum
Normal Function
Settings
Setting Default Setting
Output ON delay time
F-01
0.00s
Output OFF delay time F-02
0.00s
V-I mode slew rate select F-03
0 = CV high speed priority
Rising voltage slew rate F-04
60.00V/s (PSW 30-XX)
160.0V/s (PSW 80-XX)
320.0V/s (PSW 160-XX)
500.0V/s (PSW 250-XX)
1600V/s (PSW 800-XX)
Falling voltage slew rate F-05
60.00V/s (PSW 30-XX)
160.0V/s (PSW 80-XX)
320.0V/s (PSW 160-XX)
500.0V/s (PSW 250-XX)
1600V/s (PSW 800-XX)