System:remote, System:rwlock, System:version – GW Instek PCS-1000 User Manual
Page 75: System:output:format

COMMUNICATION INTERFACE
75
SYSTem:REMote
Set
Description
Sets the PCS-1000 operation to remote mode. All
panel keys except the Local key are locked.
Syntax
SYSTem:REMote
SYSTem:RWLock
Set
Description
Sets the PCS-1000 operation to remote mode. All
panel keys are locked, including the Local key.
Syntax
SYSTem:RWLock
SYSTem:VERSion
Query
Description
Queries the SCPI version number.
Query Syntax
SYSTem:VERSion?
Return Parameter <string>
Returns the SCPI version as a string.
Query Example
SYST:VERS?
>1999.0
Returns the SCPI version number as 1999.0.
SYSTem:OUTPut:FORMat
Set
Query
Description
Sets or queries the output formatting. There are 4
types of output formatting: 0, 1, 2, 3.
Format “0” is the default format.
The following table will show how each format
will differ from each other when the MEASure?
query is used.
Format Description
Example
0
Returns the output in
NR3 format.
+0.0E+0,-4.0E-7