p. 40 SFG-830

*OPC? Operation Complete Query

z Place an ASCII character 1 into the instrument‘s output queue when

all pending instrument operations are finished.

*CLS

Clear Status Command

z This command clears status data structures. On the other hand, it

sets the bits of the〝Standard Event Register〞and the〝Status Byte
Register〞to zero.

z The Output Queue and the MAV bit will not be cleared.

*ESE

Standard Event Status Enable Command

z *ESE, followed by a decimal value, sets the bits of the〝Standard

Event Status Enable Register〞

which correspond to that decimal value

to 1. This enables the assigned bits of the〝Standard Event Status
Register〞.

*ESE? Standard Event Status Enable Query

z This query asks for the contents of the 〝Standard Event Status Event

Register〞.The response is a decimal value, e.g.,〝255〞means all
events of the〝Standard Event Status Register〞are enabled, in other
word, all bits are 1.

*ESR? Standard Event Status Register Query

z Ask for the contents of the〝Standard Event Status Register〞. The

response is a decimal value. The query clears the register contents.