EN – 9

SYMBOL DESCRIPTION

V1PE, V2PE, V3PE

RMS value of voltage of Phase 1, Phase 2, Phase 3 with respect to PE

V12, V23, V31

RMS value of delta voltages

Freq. Mains

frequency

I1, I2, I3

RMS value of current of Phase 1, Phase 2, Phase 3 neutral

THDV1%, THDV2%, THDV3%

Harmonic distortion percentage factor of voltage of Phase 1, Phase 2, Phase 3

DCVx, Har1Vx, ,Har49Vx

(x=1,2,3) - Voltage harmonics of Phase 1, Phase 2, Phase 3

THDI1%, THDI2%, THDI3%

Harmonic distortion percentage factor of current of Phase 1, Phase 2, Phase 3

DCIx, Har1Ix, ,Har49Ix

(x=1,2,3) - Current harmonics of Phase 1, Phase 2, Phase 3

u2, uo

Unbalance indicator of voltages - Percentage value of the negative sequence

uo

Unbalance indicator of voltages - Percentage value of the zero sequence

Pt+, P1+, P2+, P3+

Absorbed active power Total, Phase 1, Phase 2, Phase 3

Eat+, Ea1+, Ea2+, Ea3+

Absorbed active energy Total, Phase 1, Phase 2, Phase 3

Qti+, Q1i+, Q2i+, Q3i+

Absorbed inductive reactive power Total, Phase 1, Phase 2, Phase 3

Erti+, Er1i+, Er2i+, Er3i+

Absorbed inductive reactive energy Total, Phase 1, Phase 2, Phase 3

Qtc+, Q1c+, Q2c+, Q3c+

Absorbed capacitive reactive power Total, Phase 1, Phase 2, Phase 3

Ertc+, Er1c+, Er2c+, Er3c+

Absorbed capacitive reactive energy Total, Phase 1, Phase 2, Phase 3

St+, S1+, S2+, S3+

Absorbed apparent power Total, Phase 1, Phase 2, Phase 3

Est+, Es1+, Es2+, Es3+

Absorbed apparent energy Total, Phase 1, Phase 2, Phase 3

Pfti+, Pf1i+, Pf2i+, Pf3i+

Values of the absorbed inductive power factors Total, Phase 1, Phase 2, Phase 3

dPfti+, dPf1i+,d Pf2i+, dPf3i+

Values of the absorbed inductive cos

Total, Phase 1, Phase 2, Phase 3

Pftc+, Pf1c+, Pf2c+, Pf3c+

Values of the absorbed capacitive power factors Total, Phase 1, Phase 2, Phase 3

dPftc+, dPf1c+, dPf2c+, dPf3c+

Values of the absorbed capacitive cos

Total. Phase 1, Phase 2, Phase 3

Pt-, P1-, P2-, P3-

Generated active power Total, Phase 1, Phase 2, Phase 3

Eat-, Ea1-, Ea2-, Ea3-

Generated active energy Total, Phase 1, Phase 2, Phase 3

Qti-, Q1i-, Q2i-, Q3i-

Generated inductive reactive power Total, Phase 1, Phase 2, Phase 3

Erti-, Er1i-, Er2i-, Er3i-

Generated inductive reactive energy Total, Phase 1, Phase 2, Phase 3

Qtc-, Q1c-, Q2c-, Q3c-

Generated capacitive reactive power Total, Phase 1, Phase 2, Phase 3

Ertc-, Er1c-, Er2c-, Er3c-

Generated capacitive reactive energy Total, Phase 1, Phase 2, Phase 3

St-, S1-, S2-, S3-

Generated apparent power Total, Phase 1, Phase 2, Phase 3

Est-, Es1-, Es2-, Es3-

Generated apparent energy Total, Phase 1, Phase 2, Phase 3

Pfti-, Pf1i-, Pf2i-, Pf3i-

Values of the generated inductive power factors Total, Phase 1, Phase 2, Phase 3

dPfti-, dPf1i-,d Pf2i-, dPf3i-

Values of the generated inductive cos

Total, Phase 1, Phase 2, Phase 3

Pftc-, Pf1c-, Pf2c-, Pf3c-

Values of the generated capacitive power factors Total, Phase 1, Phase 2, Phase 3

dPftc-, dPf1c-, dPf2c-, dPf3c-

Values of the generated capacitive cos

Total, Phase 1, Phase 2, Phase 3

Table 3: List of the parameters automatically recorded for a three-phase 3-wire system