Installing a 10 or 20 W Solar Panel and External
Battery Kit

Please refer to the TROLL Link Manual for instructions on
installing a 10 or 20 W Solar Panel and External Battery
Kit.

Installing a Battery

1. Install batteries with the terminals oriented toward the

top of the enclosure.

2. Plug the black (negative) leads into the black terminals of

the batteries first. Ensure that the terminal does not sit
between the lead clip and the plastic sheath, but that the
lead clip encompasses the battery terminal.

3. Plug the red (positive) leads into the red battery

terminals. Ensure that the terminal does not sit between
the lead clip and the plastic sheath, but that the lead clip
encompasses the battery terminal.

TROLL Link 101 and 201 Wiring Diagram

Number

Function

Wire

1

DC Com

(-)

Bulkhead black wire; solar
panel black wire

2

RS485 (-)

Bulkhead green wire

3

RS485

ground

4

RS485

(+)

Bulkhead blue wire

5

DC (+)

Bulkhead red wire; fuse blue

Number

Function

Wire

wire

Accessing the Data Center

Note that it may take up to an hour for data to be
transmitted to the Data Center, depending on the data
service package you have.

1. Open a Web browser.

2. Enter the URL:

http://www.isi-data.com

3. Enter your User ID and Password supplied by In-Situ.

Click Login.

4. The Site Index appears. The Site Index displays the site

name, most recent message received date, number of
devices at the site, and the alarm status.

5. Click a site name to view more data from that site.

6. Select a Device to view more data from that device.

If the next transmission interval has not occurred,
you should confirm that communication from all
devices in the network has been successful.

1. Ensure all components of the TROLL Link Telemetry

System have power applied.

2. From the Site Index, click the site name.

3. Click the first device listed.

4. Select Manage Device under the Site Management

heading in the left navigation bar.

5. Select View Config Messages under the Device

Config heading in the left navigation bar.

If data does not refresh at the expected rate or the site
does not display the network, contact technical support.

Maintenance

Fuse Replacement

Two fuses are located on the left edge inside of the
enclosure. The left fuse connects to the internal battery,
the right fuse connects to the charger/external power. The
fuses are 2 amp, time-delay, speed-type fuses rated for
250 VAC. Replace as needed.

Enclosure Desiccant

It is extremely important to use a properly-sized
desiccant for your deployment, and to change desiccant
before the entire volume has turned pink
. Use
enough desiccant to effectively keep electronics dry until
your next scheduled maintenance. Desiccant life span is
dependent on site conditions.

The enclosure contains one tube of desiccant that absorbs
moisture as it enters the enclosure through the vent tube.
Keep the vent tube clear of obstructions. Replace as
needed. An additional desiccant pack may be located at
the top of the enclosure. Replace or dry as needed.

Cleaning

Clean the outside of the enclosure with a soft, damp cloth.
Do not use ammonia or other harsh chemicals.