KEPCO BOP-GL 1KW Operator Manual Firmware Ver.3.05 and higher User Manual

Page 23

Advertising
background image

BOP-1K-GL 022814

1-5

PROGRAMMING CHARACTERISTICS

Analog I/O Port (6)
(see Table 2-11)

Main channel

(voltage or current)

–10V to +10V

Full range output, 20K Ohm input impedance

Protection Limit

channels:

+Voltage, –Voltage
+Current, –Current

+1V to +10V

10% to 100% of Nominal Range. Input voltage
clamped to 12V through 1K ohms. Maximum
of 0.15mA input current at 1V input voltage.
±Voltage protection controllable in Current
Mode, ±Current protection limits controllable
in Voltage mode. Set at 1.01 x nominal rating
of main channel for voltage or current.

Mode control

Voltage: open circuit or TTL logic 1
Current: short circuit or TTL logic 0

Available only when digitally activated or
through power-up setting.

Output voltage and

current analog readback

–10V to +10V

For –100% to +100% of rating for output volt-
age and current, 0.1 Ohm output impedance,
5mA max. load.

External Protection Port
(Table 2-5)

External Shutdown

Isolated input for shutdown of the

BOP (latched status)

Pulse width: 100 microseconds min.
Action delay: 100 microseconds max
Restore operation by cycling input power.

External Shutdown

Flag

Isolated output indicating

shutdown status

Action delay: 100 microseconds max

External On-Off

Flag

Isolated output indicating

output on (enabled) or off (disabled,

STANDBY) status

Action delay: 200 milliseconds max

Trigger Port (See Table 2-4)

Remote ON-OFF

(pin 2):

Operation of pin 2 is controlled by OUTP:CONT command (see Par. B.15).
Settings are STANDBY, HIGH, LOW, OFF. Either OFF or STANDBY is required if
using OUTP ON and OUTP OFF commands to control the output. This input can be
disabled (OFF), or set to BOP-MG functionality (STANDBY) (see Table 2-4).

STANDBY External Trigger Shutdown (Isolated

input. Logic 0 or short-circuit causes
the output to go to STANDBY (off,
disabled) (latched status)

Pulse width: 100

µ

S min.

Action delay: 200 mS max
Restore operation by sending OUTP ON com-
mand via remote interface.

HIGH (default) Isolated Input for controlling output

status, on or off. High or open (not
connected), output is on (enabled).
When 0 volts or short circuit applied
to the pin, output is off (disabled)

Pulse width: 6 mS min for any guaranteed unit
response.
Action delay: 200 mS max

LOW Isolated Input for controlling output

status, on or off. Logic 0 = output is
on (enabled); Logic 1 or open (not
connected) = output is off (disabled).

Pulse width: 6 mS min for any guaranteed unit
response.
Action delay: 200 mS max

OFF Trigger port disabled. Inputs applied

to pin 2 have no effect.

External Trigger

Input (pin 4)

Isolated input for trigger events

Pulse width: 100

µ

S min.

Action delay: 500

µ

S max

Remote

ON-OFF Input

Isolated input for toggling the BOP

output between output OFF (output

disabled) and output ON (output

enabled)

Action delay: 200 milliseconds max.
Logic 0 (or short circuit) for output off and
logic 1 (or open) for output on. This logic can
be reversed (see PAR. 3.3.2.1). This output
can also be disabled, or set to BOP-MG func-
tionality (STANDBY) (see Table 2-4).

External Trigger

Input

Isolated input for trigger events

Pulse width: 100 microseconds min.
Action delay: 500 microseconds max

(6) Main channel can be controlled by either external analog signal or digital remote control. Consult factory if both analog

and digital control are required.

TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION