SHOCK: (non-operating, one-half sinusoidal pulse, three
shocks to each axis):
Acceleration: 20g,
Duration: 11ms +5ms
OPERATING TEMPERATURE: See Figure 4.
STORAGE TEMPERATURE: -40
o
C to +75
o
C.
RELATIVE HUMIDITY: Operating and storage: 10% to
95% (wet bulb temp. <35
o
C non-condensing).
FUSE: Quick acting 5.0A, 250V; (5.2 x 20mm),
Littelfuse P/N 215005PF,
Kepco P/N 541-0134.
DIMENSIONS: See Figure 5.
WEIGHT: 1.7 lbs, 0.75Kg.
WARRANTY: 5 years.
FIGURE 4. % OUTPUT POWER RATING VS. AMBIENT TEMPERATURE, 5V THROUGH 48V MODELS
FIGURE 5. % OUTPUT POWER RATING VS. AMBIENT TEMPERATURE, 3.3V MODEL
NOTE:
Safety agency approvals
apply only to operation
up to 40°C.
NOTE:
Safety agency approvals
apply only to operation
up to 40°C.