KEPCO JBW 30W Series User Manual

30w series, Kepco, 30 watt single output switching power supplies

Advertising
background image

©2010, KEPCO, INC

1

Data subject to change without notice

228-1426 REV 3

KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102

http://www.kepcopower.com email: [email protected]

O P E R A T O R M A N U A L

KEPCO

An ISO 9001 Company.

JBW

30W SERIES

30 WATT SINGLE OUTPUT

SWITCHING POWER SUPPLIES

I — INTRODUCTION

SCOPE OF MANUAL. This instruction manual covers

the installation and operation of the Kepco JBW 30W

Series of RoHS (Reduction of Hazardous Substances)

compliant Switching Power Supplies.

DESCRIPTION. The Kepco JBW 30W Series consists of

four models of switching power supplies, with a single out-

put as shown in Table 1. Units may be operated with a

nominal 100 to 120V a-c and 220 to 240V a-c (input voltage

range 85 to 265 Va-c), 50-60 Hz (input frequency range 47-

440Hz.) They will also operate on 110V to 370V d-c input.

The JBW 30W Series employs a light weight ferrite core

with a fixed switching frequency. Regulation is provided by

pulse width modulation. A FET power stage, operating in

the flyback converter mode provides a smooth isolated d-c

output. A thermistor circuit prevents excessive turn-on cur-

rent surge. Overvoltage protection is provided. Current lim-

iting with automatic recovery from short circuit is featured.

Units are manufactured on an open frame pc board.

Table 1 contains specifications and operating limits of indi-

vidual JBW 30W Series models. Section II (following) con-

tains specifications and operating limits common to all JBW

30W Series Models.

II — SPECIFICATIONS

The following specifications are at nominal input voltages

and 25°C and apply to all models unless otherwise speci-

fied.

INPUT CHARACTERISTICS:

INPUT VOLTAGE: (0 to 100% load, -10 to 60°C)

Nominal 100-120V a-c, 220-240V a-c

Range: 85-265V a-c, 110 -370V d-c

NOTE: The power supply may shut down if operated at

below the input voltage range or if the input voltage

increases slowly at start up (> 1 second). To reset the

power supply, unplug the unit, wait one minute and

reapply input power.

INPUT SOURCE FREQUENCY:

Nominal:

50/60 Hz

Range:

47-440 Hz

INPUT CURRENT: (100% load at 25°C with nominal out-

put voltage):

100V a-c input:

0.65A typ., 0.86A max.

240V a-c input:

0.35A typ., 0.48A max.

INPUT PROTECTION AND SOFT START: A thermis-

tor circuit reduces start-up surge. Units are protected

against shorts by an input fuse. Fuse value 2.0A, 250V.

TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, JBW 30W SERIES

MODEL

JBW 05-6R0

JBW 12-2R5

JBW 15-2R0

JBW 24-1R3

OUTPUT VOLTS, d-c

5V

12V

15V

24V

SETTING TOLERANCE

4.75-5.25V

11.4-12.6V

14.25-15.75V

22.8-25.2V

ADJUSTMENT RANGE

FIXED

FIXED

FIXED

FIXED

MAXIMUM

OUTPUT

RATINGS

50° C amb.

6.0A/30W

2.5A/30.0W

2.0A/30.0W

1.3A/31.2W

60° C amb.

4.2A/21.0W

1.75A/21.0W

1.4A/21.0W

0.91A/21.84W

CURRENT LIMIT (AMPS)

6.3 min

2.7 min

2.1 min

1.4 min

OVP RANGE (VOLTS)

5.60 min

13.3 min

16.6 min

26.5 min

EFFI-

CIENCY

100 Va-c

75%

78%

79%

80%

240 Va-c

77%

79%

80%

81%

OUTPUT CAPACITOR

µFmax., (fixed load resistance)

10000

2200

4000

1000

RIPPLE

AND

NOISE

(1)

(mV p-p)

ripple (typ)

80

120

120

120

ripple

-10-0°C, max

140

160

160

160

spike noise

(max)

(2)

120

150

150

150

spike noise

-10-0°C, max

(2)

160

180

180

180

(1)

0 to 100% load, 0 to 50 °C, tested with 100µF electrolytic and 0.1µF film capacitors across the measuring points, and connected to the power
supply via 5.9 in (150mm) wires

(2)

Measured with a 20 MHz bandwidth oscilloscope.

Advertising