KEPCO Kit 219-0540, BOP 1000W Troubleshooting Kit User Manual

Kepco, Bop 1kw troubleshooting kit, Troubleshooting

Advertising
background image

©2008, KEPCO, INC

1

Data subject to change without notice

228-1669

I N S T R U C T I O N M A N U A L

BOP 1KW

KEPCO

KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102

http://www.kepcopower.com " email: [email protected]

An ISO 9001 Company.

TROUBLESHOOTING

KIT 219-0540

BOP 1KW

TROUBLESHOOTING KIT

1. DESCRIPTION

Kepco KIT 219-0540 contains two connector printed circuit board assemblies and one ribbon cable which allow the

A2 assembly of BOP 1000W power supply to be operated while physically removed from the chassis for trouble-

shooting purposes.

2. INSTALLATION INSTRUCTIONS

2.1 MATERIAL REQUIRED (SEE TABLE 1.)

2.2 REMOVAL PROCEDURES

1. Refer to applicable BOP 1000W Service Manual and remove the cover, then remove A1 assembly.

2. Refer to applicable BOP 1000W Service Manual and remove A2 assembly with U-shaped shroud from chassis,

then remove A2 assembly from shroud.

3. Disassemble bus bars together with A7A1 board by removing two screws from top and six screws from bottom

(see Figure 1).

4. Use two screws to attach bus bars with A7A1 to A2 assembly (see Figure 1) and connect the internal sensing

cable to header J1 of A7A1.

FIGURE 1. BUS BAR REMOVAL, REASSEMBLY

TABLE 1. MATERIAL REQUIRED

MATERIAL

LOCATION

QUANTITY

• Printed circuit board connector assembly Kepco P/N 236-2750)

Provided in this Kit

1

• Printed circuit board connector assembly Kepco P/N 236-2744)

Provided in this Kit

1

• Ribbon cable assembly (Kepco P/N 118-1217)

Provided in this Kit

1

• Instruction Manual 228-1669

Provided in this Kit

1

Advertising