Table 1. model krr 12-40 specifications, Ii — specifications – KEPCO KRR 12-40 Railroad Battery Charger User Manual

Page 2

Advertising
background image

2

228-1562

011906

KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102

http://www.kepcopower.com " email: [email protected]

II — SPECIFICATIONS

Specifications listed in Table 1 are at nominal input voltages and at 25°C unless otherwise specified.

TABLE 1. MODEL KRR 12-40 SPECIFICATIONS

SPECIFICATION

DESCRIPTION/CONDITION

RATING

Input Voltage

Nominal

100V a-c to 240V a-c

Range

85V a-c to 265V a-c

Nominal Frequency

50Hz/60Hz

Frequency Range

47Hz to 66Hz

Input Current

100V a-c to 120V a-c

8.4A a-c max.

200V a-c to 240V a-c

4.2A a-c max.

Surge, cold start, interval > 30 sec

100V a-c to 120V a-c

30A p-p max.

Surge, cold start, interval > 30 sec

200V a-c to 240V a-c

60A p-p max.

Power Factor

Rated input, rated output

0.99 typical

Efficiency

100V a-c Input

80%

240V a-c Input

84%

Leakage Current:

Per IEC 950 and UL 1950

0.75mA a-c max.

Output Voltage

Factory set to 13.50V d-c,

Adjustable range: 10.5-18.0V d-c

Output Current

Nominal @ 15V d-c Output

Ta = -10°C to 50°C, derates for Ta > 50°C

43A d-c

Short circuit value

51A d-c

Output Power

Ta = -10°C to 50°C, derates for Ta > 50°C

645W

Output Voltage

Ripple & Noise

(1)

Ripple

150mV p-p

Noise

200mV p-p

Stabilization

Source Effect

(85 to 132 V a-c and 170 to 265V a-c)

0.2% maximum

Load effect (at sensing terminals)

0.4% maximum

Temperature effect (–10° to 65°C)

1.0% maximum

Time effect (8 hours at 25°C)

0.5% maximum

Output Voltage

Temperature Compensation

Use optional temperature compensation probe

supplied 0°C to +50°C for Lead-Acid battery

3mV/(°F)(cell), 5.4mV/(°C)(cell)

Output Protection

(2)

Overvoltage

25V d-c max.

Overcurrent (internal > 30 sec)

51A d-c

Internal Overtemperature

Fan Failure

Battery Reversed

Output changed to -0.7V d-c

Output disconnected for output current > 50A d-c

Front Panel Display

Analog meter for output (charging) current

0 to 50A d-c, 5% accuracy

“Charger ON” LED

Green indicates charger is operational

“Temp Probe Error” LED

Yellow indicates that the probe is not

connected or not operational

Operation Temperature

Output performance derated above 50°C and

below 0°C

-10°C to +65°C

Storage Temperature

-30°C to 75°C

Cooling

Forced air flow - one fan

(exhaust to the left side)

Weight

9.0 lbs. (4.1 Kg.)

Dimensions

7.25 in (H). x 11.14 in. (W) x 9 in. (D)

184.2mm (H) x 283 (W) x 228.6 (D)