Figure 1. temperature compensation probe – KEPCO TEMPCO Temperature Compensation Probe User Manual

Page 2

Advertising
background image

111006

228-1594 REV 1

2

KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 " email: kepco-

FIGURE 1. TEMPERATURE COMPENSATION PROBE

TABLE 1. TEMPCO TEMPERATURE COMPENSATION PROBE SPECIFICATIONS

SPECIFICATION

RATING

CONDITION

Supply Voltage

+5V

Kepco KRR, KES Models

Range: +4V to +30V

Other Applications

Temperature Range

0°C to 35°C

Kepco KRR, KES Models

0°C to 100°C

Other Applications

Accuracy

±0.6°C typ., ±1.5°C max.(tested)

TA = 25°C

±0.9°C typ., ±2°C max.(by design)

TA = 100°C, TA = 0°C

Non-linearity

±0.2°C typ., ±0.5°C max.(by design)

0°C

TA

100°C

Sensor gain

Range: +9.8 to 10.2mV/°C, +10.0mV/°C typ.

0°C

TA

100°C

Load Regulation

±0.5mV/mA typ., ±5mV/mA max.(by design)

0

IL

1mA, 0°C

TA

100°C

Line Regulation

±0.02mV/V typ., ±0.2mV/V max.(by design)

4V

VS

30V, 0°C

TA

100°C

Quiescent Current

91.5

µ

A typ., 141

µ

A max.(by design)

VS = +30V, 0°C

TA

100°C

Quiescent Current Temperature Coefficient

+0.39

µ

A/°C typ., +0.7

µ

A/°C (by design),

4V

VS

30V

Minimum Temperature for Rated Accuracy

0°C

Kepco KRR, KES Models

Long Term Stability

±0.08°C typ.

1000 hours, with junction at TMax

Thermal Resistance

Approximately 65°C/W

Junction - ambient

Resistance

Positive and Output wires

0.05 Ohms/ft max.

TA = 25°C

Return wire

0.01 Ohms/ft max

MODEL

TEMPCO-10
TEMPCO-50
TEMPCO-100
TEMPCO-200

LENGTH "L"

10 FEET

50 FEET

100 FEET

200 FEET

Advertising