Installation – KROHNE WATERFLUX 3070 Quickstart EN User Manual
Page 19
Advertising
INSTALLATION
2
19
WATERFLUX 3070
www.krohne.com
06/2013 - 4002400602 - QS WATERFLUX 3070 R05 en
Nominal size
[inches]
Flange class
[lb]
Bolts
Max. torque
[lbs.ft]
1
1
150
4 x 1/2"
4
1½
150
4 x 1/2"
11
2
150
4 × 5/8"
18
2.5
150
8 x 5/8"
27
3
150
4 Ч 5/8"
33
4
150
8 Ч 5/8"
22
5
150
8 Ч 3/4"
33
6
150
8 Ч 3/4"
48
8
150
8 Ч 3/4"
66
10
150
12 x 7/8"
74
12
150
12 x 7/8"
106
14
150 2
12 Ч 1"
87
16
150 2
16 Ч 1"
84
18
150 2
16 Ч 1 1/8"
131
20
150 2
20 Ч 1 1/8"
118
24
150 2
20 Ч 1 1/4"
166
1 The torque values also depend on variables (temperature, bolt material, gasket material, lubricants, etc.)
outside the control of themanufacturer. Therefore these values should be regarded as indicative only.
2 No full rating (max. 145 psi).
Advertising