59 7. technical data enclosure, Supply voltage, Battery pack – KROHNE UFM 610P EN User Manual

Page 59: Keypad, Display, Outputs, Data logger, Transducers frequency velocity range, Accuracy

Advertising
background image

59

7.

TECHNICAL DATA

ENCLOSURE:

IP65 Protection Class Material

High Density P.U. Foam

Weight

< 1.5 Kg

Dimensions

275 x 150 x 55 mm

Connections

IP65 Protection Class

SUPPLY VOLTAGE:

90 – 257 V AC, 50/60 Hz

Max. power consumption

9 Watts

BATTERY PACK:

Rechargeable

15 hrs Charge Time
24 hrs Operating Time
Low Battery Indication on Display

KEYPAD:

Screened 16 Key Tactile Membrane Type

DISPLAY:

Graphic Display with Back Lighting
Temperature Range

Operating

-0

°

C to +60

°

C

Storage

-25

°

C to +60

°

C

Max. Humidity at 40

°

C 85%

OUTPUTS:

Display

Volumetric Flow

m

3

, Liters, Gallons, US Gallons

Flow Velocity

Metres/sec, feet/sec, m

3

/hr, m

3

/s,

Flow Rate (4 Significant Figures)

m

3

/hr, m

3

/min, m

3

/s, liter/min, liter/s, gallons/min, kgallon/min, Usgallon/hr

Total Flow (12 Digits)

Forward and Reverse

Continuous Battery Level Indication
Continuous Signal Level Indication
ERROR messages

Analogue

0 - 20mA / 4 – 20 mA / 0 – 16 mA

into 750

User Definable Scaling

Resolution

0.1% of full scale

Serial

RS232-C

inc. Handshaking
User Definable Scaling

Pulse

5 Volts
1 or 100 Pulse(s) per second

User Definable scaling

DATA LOGGER:

Memory Capacity

112K Bytes (53000 readings) and 20 different site set-up’s

Output

Via RS232 or displayed Graphically

Logs

Application Details
Flow Details

TRANSDUCERS

Frequency

Velocity Range

“A”

13 mm pipe

2 MHz sensors

0.2 m/sec to 7 m/sec

“A”

89 mm pipe

2 MHz sensors

0.03 m/sec to 3,75 m/sec

“B”

90 mm pipe

1 MHz sensors

0.06 m/sec to 6,75 m/sec

“B”

1000 mm pipe

1 MHz sensors

0.02 m/sec to 1.25 m/sec

“C”

300 mm pipe

1 MHz High velocity sensors

0.06 m/sec to 6 m/sec

“C”

2000 mm pipe

1 MHz High velocity sensors

0.02 m/sec to 1,7 m/sec

“D”

1000 mm pipe

0.5 MHz sensors

0.04 m/sec to 3,45 m/sec

“D”

5000 mm pipe

0.5 MHz sensors

0.014 m/sec to 1,36 m/sec

Note: On some applications transducers can be used outside their normal pipe range.
: Transducer sets “A” and “B” are standard.
: Transducer sets “C” and “D” are optional.
: A magnetic assembly is available for the Diagonal and “B” guide rail.

Standard (A,B and C)

Temperature range

-20

°

C to +100

°

C

Option (A,B and C)

Temperature range

-20

°

C to +200

°

C

ACCURACY:

+/- 2% for velocity

1 m/sec

0.02 m/sec for velocity < 1 m/sec

8.

CE MARKING

The UFM 610 P has been tested and found to conform to EN50081 - 1 Emission Standards and EN50082 - 1 Immunity
Standards. The tests were conducted by AQL - EMC Ltd, of 16 Cobham Road, Ferndown Industrial Estate, Wimborne, U.K.
BH21 7PG. The unit was tested with all cables as supplied of a maximum length of 3m. While the operation of the unit may not
be affected by the use of longer cables, KROHNE can make no statement about conformance to the above standards when these
cables are in use.

The UFM 610 P is supplied with an external battery-charging unit. This unit is manufactured by Friemann & Wolf, Geratebau
GmbH. P.O. Box 1164 D-48342 Ostbevern, Germany who have CE marked the equipment. KROHNE have purchased this
equipment on the understanding that the manufacturers have tested the unit to the relevant standards prior to CE marking the
product. KROHNE have not tested the charger unit and cannot accept responsibility for any non-conformance from the relevant
standards.

Advertising