Electrical installation – KROHNE ALTOSONIC V Installation EN User Manual
Page 13
 
 
04/2012 www.krohne.com
13
ALTOSONIC V
ELECTRICAL INSTALLATION
3
3. Electrical installation
3.1 Overview of connections
The figure below shows an overview of the electrical connections of a complete installation. 
Be aware of the units mounted in the potential explosive hazardous area. 
3.2 Installation location and wiring considerations
Cable entries 
To conform with protection category requirements, observe the following recommendations: 
Do not kink the cables 
Provide a water drip point (U bend in cable) 
 
Conduits 
The described standard version of ALTOSONIC V is equipped with cable glands for the use of 
harmonized cable. In countries where the electrical codes prescribe conduits, the mounted 
cable entries shall satisfy the IP protection class, e.g. NEMA 4 or 4X. 
 
Installation and wiring 
 When electrical codes require conduits, they must be installed in such a manner that the 
protection class of the box remains valid. As this equipment is always used in HAZLOC 
environment (Ex-zone), stopping boxes shall be used. 
 Separate conduits shall be used for mains and other wiring.