Temperature limits – KROHNE OPTISONIC 7300 Ex EN User Manual
Page 17
TEMPERATURE LIMITS
2
17
OPTISONIC 7300 / 8300
www.krohne.com
05/2012 - 7312262200 - AD EX OPTISONIC 7300/8300 R02
2.4 OPTISONIC 7000...-Ex
The OPTISONIC 7000-Ex and OPTISONIC 7000 XT-Ex have an ambient temperature in the range
of -40...+70°C. The maximum process medium temperature is listed in the table below.
2.5 OPTISONIC 8000...-Ex
The OPTISONIC 8000...-Ex high temperature (steam) flow sensor has an ambient temperature in
the range of -40...+60°C. The maximum process medium temperature is listed in the table
below.
CAUTION!
The temperature data below only applies to the meters with ultrasonic gas transducers made of
titanium (types G7.01 and G7.04). For the partly encapsulated transducer types G5.nn and G6.nn,
refer to Technical data on page 10
.
Temperature class
Maximum process temperature [ºC] at T
a
= 70ºC
Standard design
XT design
T6
80
80
T5
95
95
T4
130
130
T3
180
195
T2
n.a.
220
Temperature class
Maximum process temperature [ºC] at T
a
= 60ºC
T6
80
T5
95
T4
130
T3
195
T2
290
T1
440