Technical data – KROHNE OPTIMASS 8000K EN User Manual

Page 30

Advertising
background image

6

TECHNICAL DATA

30

OPTIMASS 8000K

www.krohne.com

08/2010 - 4000921002 - MA OPTIMASS 8000k R02 en

Operating conditions

Maximum flow rates

Maximum flow rates

Maximum flow rates

Maximum flow rates

S15

3510 kg/h / 128.7 lbs/min

S25

11700 kg/h / 429 lbs/min

S40

41600 kg/h / 1525.3 lbs/min

S80

110500 kg/h / 4051.6 lbs/min

S100

325000 kg/h / 11916.6 lbs/min

Assumes operating density 1000 kg/m

3

/ 62.4 lb/ft

3

Ambient temperature

Ambient temperature

Ambient temperature

Ambient temperature

Compact version with Aluminium

converter

Standard temperature range: -40...+60°C / -40…+140°F

Cryogenic temperature range: -25...+40°C / -13…+104°F

Compact version with Stainless Steel

converter

Standard temperature range: -40...+55°C / -40…+131°F

Cryogenic temperature range: -25...+40°C / -13…+104°F

Remote versions

Standard temperature range: -40...+65°C / -40…+149°F

Cryogenic temperature range: -20...+65°C / -4…+149°F

Hazardous Area versions

Refer to temperature limits

Process temperature

Process temperature

Process temperature

Process temperature

Standard temperature range

Standard temperature range

Standard temperature range

Standard temperature range

Safe area (compact and remote version)

-70…+230°C / -94…+440°F

Hazardous area (standard temperature,

compact version only)

-40…+190°C / -40…+370°F

Hazardous area (standard temperature,

remote version only)

-40…+230°C / -40…+440°F

Hygienic connections

-70…+150°C / -94…+302°F

Cryogenic temperature range

Cryogenic temperature range

Cryogenic temperature range

Cryogenic temperature range

Safe area

-195…+40°C / -310…+104°F

Hazardous area

-195…+40°C / -310…+104°F

Nominal pressure at 20

Nominal pressure at 20

Nominal pressure at 20

Nominal pressure at 20°C / 68

C / 68

C / 68

C / 68°F

F

F

F

Measuring tube

Measuring tube

Measuring tube

Measuring tube

PED 97/23/EC

-1…100 barg / -14.5…1450 psig

FM

Pending

CRN / ASME B31.3

Pending

Fluid properties

Fluid properties

Fluid properties

Fluid properties

Permissible physical condition

Liquids, gases, slurries

Permissible gas content (volume)

Contact manufacturer for information.

Permissible solid content (volume)

Contact manufacturer for information.

Protection category (acc. to EN 60529)

IP 67, NEMA 4X

Installation conditions

Inlet runs

None required

Outlet runs

None required

MA_OPTIMASS_8000k_en_100817_4000921002_R02.book Page 30 Tuesday, August 17, 2010 2:08 PM

Advertising