Installation – KROHNE OPTISWIRL 4070 Quickstart EN User Manual
Page 12

2
INSTALLATION
12
OPTISWIRL 4070
www.krohne.com
06/2010 - 4000122102 - QS OPTISWIRL R04 en
2.3.6 Turning the display
Turn the display as follows:
• Disconnect the power supply from the measuring device.
• Unscrew the cover in front of the display 1 from the connection housing.
• Pull the display 2 carefully a few centimetres out of the anchor fitting and turn it to the
required position 3.
• Press the display onto the spacer pins 4, until it clicks.
• Turn the cover with gasket 5 back onto the housing and tighten it by hand.
DANGER!
All work on the device electrics may only be carried out by appropriately trained personnel. The
regional occupational health and safety directives must always be observed.
INFORMATION!
If the measuring device is installed in a vertical pipe, you will have to turn the display by 90°; if
installed below a pipe, turn 180°.
Figure 2-7: Turning the display
QS_OPTISWIRL4070_R04_en_122102_PRT.book Page 12 Monday, June 7, 2010 8:51 AM