General safety information, 5 equipment protection levels (epl), 6 nameplates – KROHNE DW 181-182-183-184 ATEX EN User Manual

Page 5

Advertising
background image

GENERAL SAFETY INFORMATION

1

5

DW 18 SERIES

www.krohne.com

11/2011 - 4001528201 - AD ATEX DW181-184 R01 en

1.4.4 Definitions of device categories

Category 1

Category 1

Category 1

Category 1
The device is installed in hazardous areas requiring Category 1 G or 1 D equipment.

Category 1/2

Category 1/2

Category 1/2

Category 1/2
The switch housing is installed in hazardous areas requiring Category 2 G or 2 D equipment. The
measuring tube is installed in hazardous areas requiring Category 1 G or 1 D equipment.

1.5 Equipment protection levels (EPL)

1.5.1 Ex ia-approved devices

The Ex ia-approved device is certified for applications for which an EPL of Ga or Da is necessary.

1.5.2 Ex d- / Ex tb-approved devices

The Ex d-approved device is suitable is certified for applications for which an EPL of Gb or Db is
necessary.

1.5.3 Definitions of equipment protection levels

EPL Ga or Da

EPL Ga or Da

EPL Ga or Da

EPL Ga or Da
The device is installed in hazardous areas that must have equipment with a very high level of
protection. The device is not a source of ignition in usual conditions of operation or when
possible or unusual faults occur.

EPL Gb or Db

EPL Gb or Db

EPL Gb or Db

EPL Gb or Db
The device is installed in hazardous areas that must have equipment with a high level of
protection. The device is not a source of ignition in usual conditions of operation or when
possible faults occur. It is possible that this does not include frequent faults.

1.6 Nameplates

INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.