4 switch on phase, Internal check of the electronics – KROHNE OPTISOUND 3030C 4wire EN User Manual
Page 21

4 ... 20 mA
PE
/ L
/ N
L1 N
GND
1
2
1
2
3
4
4...20mA
IS
Fig. 19: Wiring plan, double chamber housing
1
Supply voltage
2
Signal output
5.4 Switch on phase
After OPTISOUND 3030 C is connected to power supply, the
instrument carries out a self-test for approx. 30 seconds. The
following steps are carried out:
l
Internal check of the electronics
l
Indication of the instrument type, the firmware version as
well as the sensor TAGs (sensor name)
l
Output signal jumps briefly (approx. 10 seconds) to the set
fault current
Then the actual measured value is displayed and the
corresponding current is transmitted to the cable.
1)
1)
The values correspond to the actual level as well as to the settings already
carried out, e.g. default setting.
Wiring plan
Switch on phase
OPTISOUND 3030 C - 4 ... 20 mA/HART - four-wire
21
Connecting to power supply
30512
-EN
-050914