3.3 Operation

With the factory setting, products with a density of >0.02 g/cm³

(>0.0008 lbs/in³) can be measured. The instrument can also

be adapted to products with lower density >0.008 g/cm³

(>0.0003 lbs/in³).
On the electronics module you will find the following indicating

and adjustment elements:

l

signal lamp for indication of the switching condition (green/

red)

l

potentiometer for adaptation to the product density

l

Mode switch for selecting the switching condition (min./

max.)

3.4 Storage and transport

Your instrument was protected by packaging during transport.

Its capacity to handle normal loads during transport is assured

by a test according to DIN 55439.
The packaging of standard instruments consists of environ-

ment-friendly, recyclable cardboard. In addition, the sensor is

provided with a protective cover of cardboard. For special

versions PE foam or PE foil is also used. Dispose of the

packaging material via specialised recycling companies.

l

Storage and transport temperature see "Supplement -

Technical data - Ambient conditions"

l

Relative humidity 20 … 85 %

Packaging

Storage and transport tem-

perature

OPTISWITCH 3300 C - with contactless electronic switch