background image

Electromechanical data
Cable entry/plug

2)

- Single chamber housing

l

1x cable entry M20x1.5 (cable-ø 5 … 9 mm),

1x blind stopper M20x1.5

or:

l

1x closing cap ½ NPT, 1x blind plug ½ NPT

or:

l

1x plug (depending on the version), 1x blind

plug M20x1.5

Screw terminals

for wire cross-section up to 1.5 mm²

(0.0023 in²)

Adjustment elements
Sensitivity switch
- 0.5

0.5 … 2.5 g/cm³ (0.018 … 0.9 oz/in³)

- 0.7

0.7 … 2.5 g/cm³ (0.025 … 0.9 oz/in³)

Voltage supply
Supply voltage

11 … 36 V DC (via the signal conditioning

instrument)

Electrical protective measures
Protection

IP 66/IP 67

Overvoltage category

III

Protection class

II

Approvals

3)

ATEX II 1G, 1/2G, 2G EEx ia IIC T6
ATEX II 1/2G, 2G EExd d IIC T6

4)

Overfill protection acc. to WHG
Ship approvals

2)

Depending on the version M12x1, according to DIN 43650, Harting, Am-

phenol-Tuchel, 7/8" FF.

3)

Deviating data in Ex applications: see separate safety instructions.

4)

Only with Aluminium housing.