Surface quality
- Standard
R
a
approx. 3 µm (approx. 1.18
-4
in)
- Hygienic version 3A (OPTISWITCH
5150 C)
R
a
<0.8 µm (<3.15
-5
in)
Process fittings
- Thread
G¾ A, ¾ NPT, G1 A, 1 NPT
- Flanges
DIN from DN 25, ANSI from 1"
- hygienic fittings
Bolting DN 40 PN 40, Tri-Clamp 1", Tri-Clamp
1½" PN 10, conus DN 25 PN 40, Tuchenhagen
Varivent DN 50 PN 10
High voltage test (enamel)
max. 5 KV
Gas-tight leadthrough (optional)
- leakage rate
<10
-6
mbar l/s
- pressure resistance
PN 64
- hygienic fittings
Bolting DN 40 PN 40, Tri-Clamp 1", Tri-Clamp
1½" PN 10, conus DN 25 PN 40, Tuchenhagen
Varivent DN 50 PN 10
Output variable
Output
relay output (DPDT), 2 floating spdts
Turn-on voltage
- min.
10 mV
- max.
253 V AC, 253 V DC
Switching current
- min.
10 µA
- max.
3 A AC, 1 A DC
Breaking capacity
- min.
50 mW
- max.
750 VA AC, 54 W DC
If inductive loads or stronger currents are
switched through, the gold plating on the relay
contact surface will be permanently damaged.
The contact is then no longer suitable for
switching low-level signal circuits.
Contact material (relay contacts)
AgNi or AgSnO and Au plated
OPTISWITCH 5100 C, 5150 C - with relay output
25
Supplement
30426
-EN
-060831