Technical data – KROHNE OPTITEMP TRA-TCA Plus EN User Manual
Page 55

TECHNICAL DATA
7
55
OPTITEMP TRA/TCA PLUS
www.krohne.com
01/2012 - 4000630301 - MA OPTITEMP TRA/TCA Plus R01
TRA/TCA-TS52, -TS53, -TS54 with DIN-neck tube
Neck tube length "a"
Insertion length "b"
Thermowell length "c" Measuring insert
length
[mm]
["]
[mm]
["]
[mm]
["]
[mm]
["]
165
6.5
100
3.9
145
5.7
318
12.5
150
5.9
195
7.7
368
14.5
200
7.9
245
9.6
418
16.5
250
9.8
295
11.6
468
18.4
300
11.8
345
13.6
518
20.4
350
13.8
395
15.6
568
22.4
TRA/TCA-TS52, -TS53, -TS54 with ASME-neck tube
Neck tube length "a"
Insertion length "b"
Thermowell length "c" Measuring insert
length
[mm]
["]
[mm]
["]
[mm]
["]
[mm]
["]
76
3
100
3.9
145
5.7
243
9.6
150
5.9
195
7.7
293
11.5
200
7.9
245
9.6
343
13.5
250
9.8
295
11.6
393
15.5
300
11.8
345
13.6
443
17.4
350
13.8
395
15.6
493
19.4
TRA/TCA-TS52, -TS53, -TS54 with ASME-neck tube
Neck tube length "a"
Insertion length "b"
Thermowell length "c" Measuring insert
length
[mm]
["]
[mm]
["]
[mm]
["]
[mm]
["]
152
6
100
3.9
145
5.7
319
12.6
150
5.9
195
7.7
369
14.5
200
7.9
245
9.6
419
16.5
250
9.8
295
11.6
469
18.5
300
11.8
345
13.6
519
20.4
350
13.8
395
15.6
569
22.4
.backup.book Page 55 Tuesday, January 10, 2012 11:57 AM